/[svn]/gigedit/trunk/ChangeLog
ViewVC logotype

Diff of /gigedit/trunk/ChangeLog

Parent Directory Parent Directory | Revision Log Revision Log | View Patch Patch

revision 3781 by schoenebeck, Fri May 29 21:49:48 2020 UTC revision 4082 by schoenebeck, Fri Jan 26 17:24:43 2024 UTC
# Line 1  Line 1 
1  Version SVN trunk (?)  Version 1.2.1 (2024-01-26)
2    
3      * Use libgig's new IO-per-thread feature to avoid file I/O concurrency
4        issues with .gig files in multi-threaded environment.
5      * configure: make it clear that liblinuxsampler is mandatory for this
6        version of gigedit.
7      * Live-editing: Show an error message on terminal if sampler's libgig
8        version and Gigedit's libgig version are not binary compatible.
9    
10    Version 1.2.0 (2021-05-09)
11    
12    * Script Editor: Added syntax highlighting support for standard measurement    * Script Editor: Added syntax highlighting support for standard measurement
13      units (and their potential metric prefix).      units (and their potential metric prefix).
# Line 57  Version SVN trunk (?) Line 66  Version SVN trunk (?)
66      editor for that double clicked script.      editor for that double clicked script.
67    * Combine Tool: Fixed wrong number of output dimension zones being created    * Combine Tool: Fixed wrong number of output dimension zones being created
68      (on unequal, odd dimension zone count between two input instruments).      (on unequal, odd dimension zone count between two input instruments).
69      * Combine Tool: Prevent NULL samples in combined instrument (if source
70        dimension had less zones than output dimension).
71      * When removing sample reference by clicking the NULL button, do that
72        actually for the appropriate set of all dimension regions currently being
73        selected by user.
74      * Fixed instrument list's 'script count' column not being updated after
75        having duplicated an instrument.
76      * Refactored ModelColumns -> InstrumentsModel,
77        m_Columns -> m_InstrumentsModel, m_TreeView -> m_TreeViewInstruments,
78        m_refTreeModel -> m_refInstrumentsTreeModel,
79        m_refTreeModelFilter -> m_refInstrumentsModelFilter.
80      * Fixed MainWindow::get_instrument() having returned wrong instrument if
81        instrument name filter was used.
82      * Fixed wrong script slots being shown if instrument name filter was used.
83      * Fixed wrong instrument being selected in instruments menu if instrument
84        name filter was used.
85      * Fixed instrument properties dialog having displayed properties of wrong
86        instrument if instrument name filter was used.
87      * Fixed wrong instruments being duplicated if instrument name filter was used.
88      * Fixed wrong instruments being removed if instrument name filter was used.
89      * Fixed instrument reordering by drag and drop when instrument name filter
90        was used.
91      * Fixed wrong instruments being selected for combination if instrument name
92        filter was used.
93      * Fixed double selection if instrument name filter was active while clicking
94        an instrument from the list.
95      * Main Window: auto save & restore the vertical splitter position.
96    
97  Version 1.1.1 (2019-07-27)  Version 1.1.1 (2019-07-27)
98    

Legend:
Removed from v.3781  
changed lines
  Added in v.4082

  ViewVC Help