revision 1639 by schoenebeck, Sat Jan 12 14:13:46 2008 UTC revision 1777 by persson, Mon Sep 15 16:58:10 2008 UTC
# Line 5  Version CVS HEAD (?) Line 5  Version CVS HEAD (?)
5        causing e.g. the libgig test to fail when        causing e.g. the libgig test to fail when
6        "./configure --disable-jack-driver" was used        "./configure --disable-jack-driver" was used
7        (patch by Alexis Ballier)        (patch by Alexis Ballier)
8        - fixed compilation with gcc 4.3
9    
10    * general changes:    * general changes:
11      - bugfix: on some POSIX systems instrument editor plugins refused to      - bugfix: on some POSIX systems instrument editor plugins refused to
# Line 12  Version CVS HEAD (?) Line 13  Version CVS HEAD (?)
13        (fixes bug #70, patch by Ronald Baljeu)        (fixes bug #70, patch by Ronald Baljeu)
14      - fixed endless loop which occured when loading an instrument editor      - fixed endless loop which occured when loading an instrument editor
15        plugin DLL on Windows systems failed        plugin DLL on Windows systems failed
16        - fixed memory leaks that occurred when liblinuxsampler was unloaded
17        - optimized the SynchronizedConfig class so it doesn't wait
18          unnecessarily long after an update
19        - added support for notifying instrument editors on note-on / note-off
20          events (e.g. to highlight the pressed keys on the virtual keyboard
21          of gigedit)
22        - added support for triggering notes by instrument editors (see above)
23        - be verbose on DLL load errors (on Linux)
24        - fixed di-harmonic triangle LFO implementation (this LFO implementation
25          is only used by very few systems, most pick the int math
26          implementation, which is usually faster)
27        - fixes for audio drivers with varying buffer sizes
28        - experimental support for running LinuxSampler as a DSSI, LV2 and
29          VST plugin
30    
31    * audio driver:    * audio driver:
32      - removed the nonsense audio channel constraint (which was hard coded to      - removed the nonsense audio channel constraint (which was hard coded to
# Line 20  Version CVS HEAD (?) Line 35  Version CVS HEAD (?)
35        opposed to the LSCP specs        opposed to the LSCP specs
36      - bugfix: the SAMPLERATE parameter of some drivers (e.g. JACK)      - bugfix: the SAMPLERATE parameter of some drivers (e.g. JACK)
37        reflected the wrong value        reflected the wrong value
38        - fixed a memory management bug in ASIO driver
39        - Makefile fix: JACK_CFLAGS wasn't used
40        - JACK: use jack_client_open instead of the deprecated
41          jack_client_new
42    
43      * MIDI driver:
44        - added JACK MIDI driver
45        - dispatch bank select as ordinary CC as well, the user might seriously
46          want to (mis)use it for some purpose ("fixed" in all current MIDI
47          input drivers: ALSA, CoreMIDI, JACK, MidiShare, MME)
48    
49    * instruments database:    * instruments database:
50      - avoid time consuming samples scanning when adding instruments      - avoid time consuming samples scanning when adding instruments
51        to the instruments database        to the instruments database
52        - added support for handling lost files in the instruments database
53    
54      * Gigasampler format engine:
55        - fixed a memory leak that could happen when a channel was deleted
56          while notes were playing
57        - made it possible to load an instrument even if the audio thread
58          isn't running
59        - added partial support for the "Controller Triggered" MIDI rule,
60          enough for piano gigs with pedal noise samples
61        - minor fix: only mark FX sends as being modified if really the
62          respective FX send MIDI controller was used
63        - added support for GM global device volume SysEx message
64          (can be selected at compile time to either apply globally to the
65          whole sampler [default] or only to the sampler channels that are
66          connected to the respective MIDI input port the SysEx message arrived
67          on)
68        - bugfix: notes triggered at position 0 in the audio buffer were
69          sometimes wrongly killed in the same buffer, causing no sound to
70          be played
71        - added support for chromatic / drumkit mode Roland GS Sysex message
72          which is usally used to switch a part between chromatic sounds and
73          drumkit sounds (as opposed to their common default setting of MIDI
74          part 10 being a drumkit part and all other ones chromatic parts), in
75          LS however one can switch between the first 16 MIDI instrument maps
76          defined for the sampler
77        - made it possible to create multiple sample channels even if the
78          audio thread isn't running
79    
80      * LSCP server:
81        - added new LSCP event "CHANNEL_MIDI" which can be used by frontends to
82          react on MIDI data arriving on certain sampler channels (so far only
83          Note-On and Note-Off events are sent via this LSCP event)
84        - added new LSCP event "DEVICE_MIDI" which can be used by frontends to
85          react on MIDI data arriving on certain MIDI input devices (so far only
86          Note-On and Note-Off events are sent via this LSCP event)
87        - added new LSCP commands: FIND LOST DB_INSTRUMENT_FILES and
88          SET DB_INSTRUMENT FILE_PATH
89        - added new LSCP command: SEND CHANNEL MIDI_DATA which can be used by
90          frontends to send MIDI messages to specific sampler channel
91        - added two additional fields to GET FILE INSTRUMENT INFO command -
92          KEY_BINDINGS and KEYSWITCH_BINDINGS
93        - bugfix: the bank number provided by MIDI_INSTRUMENT_INFO notifications
94          was incorrect
95        - Optimized the retrieval of the MIDI instrument mappings
96    
97      * Bug fixes:
98        - fixed a crash which occurs when removing a sampler channel waiting
99          to start instrument loading after another channel
100    
101    
102  Version 0.5.1 (6 December 2007)  Version 0.5.1 (6 December 2007)
103    

Legend:
Removed from v.1639  
changed lines
  Added in v.1777

  ViewVC Help