/[svn]/qsampler/trunk/ChangeLog
ViewVC logotype

Contents of /qsampler/trunk/ChangeLog

Parent Directory Parent Directory | Revision Log Revision Log


Revision 753 - (show annotations) (download)
Wed Aug 24 17:44:59 2005 UTC (18 years, 7 months ago) by capela
File size: 6338 byte(s)
Attempt to bring those aging autoconf templates to date;
  sample SPEC file for RPM build is now being included and
  generated at configure time.

1 Qsampler - A LinuxSampler Qt GUI Interface
2 ------------------------------------------
3
4 ChangeLog
5
6 CVS HEAD
7
8 * Attempt to bring those aging autoconf templates to date;
9 sample SPEC file for RPM build is now being included and
10 generated at configure time.
11
12 * Set to use QApplication::setMainWidget() instead of
13 registering the traditional lastWindowClosed() signal
14 to quit() slot, just to let the -geometry command line
15 argument have some effect on X11.
16
17 * Added MUTE/SOLO buttons to individual channel strips.
18
19 * Fixed compilation error which occured when Qt was
20 compiled with -no-stl.
21
22
23 0.1.2 2005-06-23 Even minor workings needs a rest.
24
25 * Fixed output disability when messages limit option is
26 turned off (thanks to Wolfgang Woehl for spotting this
27 one, while on qjackctl).
28
29 * Added CHANNEL_INFO event feedback notification handling;
30 minor stream/voice usage auto-refresh cycle optimization.
31
32
33 0.1.1 2005-06-12 The mantra of bugfixes.
34
35 * New improved and full-featured application icon, thanks
36 to Christian Schoenebeck design.
37
38 * Fixed refresh cycle of channel strips that are found
39 in an error state, which was preventing correct channel
40 info updates.
41
42 * Device configuration now accessible on toolbar. Added
43 buddy text label to device port/channel combobox on the
44 device dialog.
45
46 * Include libgig version info on command line request (-v).
47
48 * Minor configure and Makefile install fixes, as Debian and
49 Mac OS X specialties. Also, install does the right thing
50 with target file modes (thanks to Matt Flax and Ebrahim
51 Mayat, for pointing these out).
52
53
54 0.1.0 2005-05-23 Device configuration breakthrough.
55
56 * Device configuration is now complete (EXPERIMENTAL).
57
58 * [bug #9] Fixed for a LSCP command syntax convention
59 consistency, regarding the enumeration of available
60 sampler engines, Audio and MIDI drivers.
61
62 * [bug #13] Update instrument names list when a new
63 instrument file is select on the channel setup dialog.
64
65 * Show appropriate message in channel strip while loading
66 an instrument.
67
68 * Show libgig version in About box (in case libgig is used).
69
70
71 0.0.5 2005-03-04 Fifth alpha-release.
72
73 * Fixed device driver type channel information gathering,
74 which was severely flawed, dropping all channel session
75 configurations to the default audio driver type (which
76 is ALSA) unexpectedly.
77
78 * Channels are now properly renumbered when saving to a
79 session LSCP script, assuming that it should be always
80 loaded from scratch (i.e. zero channels).
81
82 * Disabled MIDI port setting on channel dialog, and on
83 session file save, as its use is still troublesome.
84
85 * Added new menu and toolbar option: Reset All Channels.
86
87 * Channel setup changes are now properly filtered, as for
88 only those settings that are actually changed gets applied;
89 change information are now also posted to messages window.
90
91 * Drag-and-drop of either session files (LSCP scripts) or
92 instrument files (GIG) are now supported. Multiple files
93 drop is allowed, but it only makes sense for instrument
94 files, each one prompting to create a new sampler channel.
95
96 * Drag-and-drop to an existing channel strip is now also
97 featured, allowing the in-place change of the channel
98 sampler instrument file.
99
100 * Actual instrument names are now optionally retrieved
101 from the instrument file, even though libgig is available,
102 avoiding excessively annoying load times while on the
103 channel dialog, when huge instrument files are selected.
104
105 * Set to ignore the SIGPIPE ("Broken pipe") signal, where
106 available, as the default handler is usually fatal when
107 a JACK client is zombified abruptly.
108
109 * Messages window limit is now enforced only when the line
110 count exceeds in one third the user configured line count
111 maximum; if Qt 3.2.0+ is in use, the QTextView widget is
112 otherwise set to the optimized Qt::LogText format.
113
114
115 0.0.4 2004-11-19 Fourth alpha-release.
116
117 * Instrument index selection now made via combo box widget;
118 actual instrument names are now properly retrieved from
119 the instrument file, provided if libgig is available.
120
121 * Sampler channels strips are just created if, and only if,
122 the respective channel setup dialog is actually accepted,
123 following common user-interface guidelines.
124
125 * Almost complete rewrite of sampler channel strips internal
126 control structures.
127
128 * Sampler reset command action added to menu and toolbar.
129
130 * MIDI channel selection is now a dropdown list, allowing
131 the explicit selection for "All" channels input per sampler
132 channel (omni mode).
133
134 * Channel strip display glass effect has changed background
135 color to black (was green), being now an user option.
136
137 * Minor configure fixes.
138
139
140 0.0.3 2004-07-06 Third alpha-release.
141
142 * Mon-modal intrument file loading and status support.
143
144 * Effective MIDI input port setting on channel dialog,
145 and on session file save.
146
147 * Channel dialog gets sensible engine and driver defaults
148 on create time.
149
150 * Implied channel reset on successful instrument load.
151
152
153 0.0.2 2004-06-15 Pre-revolutionary release.
154
155 * The channel context menu is also accessible by right-clicking
156 over the empty workspace area.
157
158 * Added small wait event loop on qsamplerMainForm::stopServer(),
159 so let local server terminate gracefully and stabilize, and
160 avoiding a probable segfault on exit, which was preventing the
161 correct salvage of settings and configuration.
162
163 * Maximum channel volume percent setting is now a global option,
164 provided to override the default (which is 100%).
165
166 * Client/server transaction timeout option upper limit has been
167 increased from 5000 to 60000 milliseconds.
168
169 * A channel context menu is now featured, by right-clicking over
170 each sampler channel strip.
171
172 * Commented SET CHANNEL MIDI_INPUT_PORT command from
173 qsamplerMainForm::saveSessionFile(), it has no effect.
174
175 * Insert a n #include <unistd.h> on qsamplerMessages.cpp, between
176 a #if !defined(WIN32) clause.
177
178 * An initial non zero value (0.8) is now set for volume of every
179 new sampler channel strip.
180
181 * The order to load/save and setup channel settings is now as
182 suggested in the following lines:
183
184 SET CHANNEL AUDIO_OUTPUT_TYPE ...
185 SET CHANNEL MIDI_INPUT_TYPE ...
186 SET CHANNEL MIDI_INPUT_CHANNEL ...
187 LOAD ENGINE ...
188 LOAD INSTRUMENT ...
189 SET CHANNEL VOLUME ...
190
191
192 0.0.1 2004-06-05 Primordial alpha release.
193

  ViewVC Help
Powered by ViewVC