/[svn]/qsampler/trunk/ChangeLog
ViewVC logotype

Contents of /qsampler/trunk/ChangeLog

Parent Directory Parent Directory | Revision Log Revision Log


Revision 995 - (show annotations) (download)
Thu Dec 21 13:58:52 2006 UTC (17 years, 3 months ago) by capela
File size: 8282 byte(s)
* Manual sampler reset also resets all MIDI instrument maps.

1 Qsampler - A LinuxSampler Qt GUI Interface
2 ------------------------------------------
3
4 ChangeLog
5
6 CVS HEAD
7
8 * Manual sampler reset also resets all MIDI instrument maps.
9
10 * Revised error verbosity in general and on session load/save;
11 hour-glass wait cursor is now displayed on session load/save;
12 keyboard shortcuts changed on MIDI instruments view context;
13 improved channel strip arrangement on session open/load;
14 instrument map entry removal confirmation (as optional);
15 corrected some tooltip text strings.
16
17 * MIDI instrumeent map program numbers are now displayed in
18 the range 1-128, instead of the internal 0-127.
19
20 * Most top-level widgets were missing the normal-widget flag,
21 which were causing some sticky size behavior while on some
22 window managers.
23
24 * Added preliminary MIDI instrument mapping support; now
25 with an instrument list widget and editing capabilities.
26
27 * GPL address update.
28
29
30 0.1.3 2006-06-01 Its been a long year isn't it?
31
32 * Changed deprecated copyright attribute to license,
33 on qsampler.spec (RPM).
34
35 * Added configure support for x86_64 libraries (UNTESTED).
36
37 * Optional specification of alternate liblscp and libgig
38 installation paths have been added to configure command
39 arguments (--with-liblscp, --with-libgig).
40
41 * Whenever the listing of actual instrument names is not an
42 option (e.g. due to lack of libgig support), the whole
43 number of selectable instrument items is now being graciously
44 increased from just the bare 8 (eight) right up through 100
45 (one hundred), on the sampler channel setup dialog.
46
47 * The selection buttons, on the right of the Instrument, Audio
48 and MIDI devices combo-boxes, on the sampler channel dialog,
49 are now expected to be a little better looking than it was
50 before, at least for those Mac OS X eyes.
51
52 * Minor fixing on the initial messages dock-window height.
53
54 * Audio output channel routing configuration finally hits
55 the sampler channel dialog, at last! (EXPERIMENTAL).
56
57 * All widget captions changed to include proper application
58 title name prefix.
59
60 * Attempt to bring those aging autoconf templates to date;
61 sample SPEC file for RPM build is now being included and
62 generated at configure time.
63
64 * Set to use QApplication::setMainWidget() instead of
65 registering the traditional lastWindowClosed() signal
66 to quit() slot, just to let the -geometry command line
67 argument have some effect on X11.
68
69 * Added MUTE/SOLO buttons to individual channel strips.
70
71 * Fixed compilation error which occured when Qt was
72 compiled with -no-stl.
73
74
75 0.1.2 2005-06-23 Even minor workings needs a rest.
76
77 * Fixed output disability when messages limit option is
78 turned off (thanks to Wolfgang Woehl for spotting this
79 one, while on qjackctl).
80
81 * Added CHANNEL_INFO event feedback notification handling;
82 minor stream/voice usage auto-refresh cycle optimization.
83
84
85 0.1.1 2005-06-12 The mantra of bugfixes.
86
87 * New improved and full-featured application icon, thanks
88 to Christian Schoenebeck design.
89
90 * Fixed refresh cycle of channel strips that are found
91 in an error state, which was preventing correct channel
92 info updates.
93
94 * Device configuration now accessible on toolbar. Added
95 buddy text label to device port/channel combobox on the
96 device dialog.
97
98 * Include libgig version info on command line request (-v).
99
100 * Minor configure and Makefile install fixes, as Debian and
101 Mac OS X specialties. Also, install does the right thing
102 with target file modes (thanks to Matt Flax and Ebrahim
103 Mayat, for pointing these out).
104
105
106 0.1.0 2005-05-23 Device configuration breakthrough.
107
108 * Device configuration is now complete (EXPERIMENTAL).
109
110 * [bug #9] Fixed for a LSCP command syntax convention
111 consistency, regarding the enumeration of available
112 sampler engines, Audio and MIDI drivers.
113
114 * [bug #13] Update instrument names list when a new
115 instrument file is select on the channel setup dialog.
116
117 * Show appropriate message in channel strip while loading
118 an instrument.
119
120 * Show libgig version in About box (in case libgig is used).
121
122
123 0.0.5 2005-03-04 Fifth alpha-release.
124
125 * Fixed device driver type channel information gathering,
126 which was severely flawed, dropping all channel session
127 configurations to the default audio driver type (which
128 is ALSA) unexpectedly.
129
130 * Channels are now properly renumbered when saving to a
131 session LSCP script, assuming that it should be always
132 loaded from scratch (i.e. zero channels).
133
134 * Disabled MIDI port setting on channel dialog, and on
135 session file save, as its use is still troublesome.
136
137 * Added new menu and toolbar option: Reset All Channels.
138
139 * Channel setup changes are now properly filtered, as for
140 only those settings that are actually changed gets applied;
141 change information are now also posted to messages window.
142
143 * Drag-and-drop of either session files (LSCP scripts) or
144 instrument files (GIG) are now supported. Multiple files
145 drop is allowed, but it only makes sense for instrument
146 files, each one prompting to create a new sampler channel.
147
148 * Drag-and-drop to an existing channel strip is now also
149 featured, allowing the in-place change of the channel
150 sampler instrument file.
151
152 * Actual instrument names are now optionally retrieved
153 from the instrument file, even though libgig is available,
154 avoiding excessively annoying load times while on the
155 channel dialog, when huge instrument files are selected.
156
157 * Set to ignore the SIGPIPE ("Broken pipe") signal, where
158 available, as the default handler is usually fatal when
159 a JACK client is zombified abruptly.
160
161 * Messages window limit is now enforced only when the line
162 count exceeds in one third the user configured line count
163 maximum; if Qt 3.2.0+ is in use, the QTextView widget is
164 otherwise set to the optimized Qt::LogText format.
165
166
167 0.0.4 2004-11-19 Fourth alpha-release.
168
169 * Instrument index selection now made via combo box widget;
170 actual instrument names are now properly retrieved from
171 the instrument file, provided if libgig is available.
172
173 * Sampler channels strips are just created if, and only if,
174 the respective channel setup dialog is actually accepted,
175 following common user-interface guidelines.
176
177 * Almost complete rewrite of sampler channel strips internal
178 control structures.
179
180 * Sampler reset command action added to menu and toolbar.
181
182 * MIDI channel selection is now a dropdown list, allowing
183 the explicit selection for "All" channels input per sampler
184 channel (omni mode).
185
186 * Channel strip display glass effect has changed background
187 color to black (was green), being now an user option.
188
189 * Minor configure fixes.
190
191
192 0.0.3 2004-07-06 Third alpha-release.
193
194 * Mon-modal intrument file loading and status support.
195
196 * Effective MIDI input port setting on channel dialog,
197 and on session file save.
198
199 * Channel dialog gets sensible engine and driver defaults
200 on create time.
201
202 * Implied channel reset on successful instrument load.
203
204
205 0.0.2 2004-06-15 Pre-revolutionary release.
206
207 * The channel context menu is also accessible by right-clicking
208 over the empty workspace area.
209
210 * Added small wait event loop on qsamplerMainForm::stopServer(),
211 so let local server terminate gracefully and stabilize, and
212 avoiding a probable segfault on exit, which was preventing the
213 correct salvage of settings and configuration.
214
215 * Maximum channel volume percent setting is now a global option,
216 provided to override the default (which is 100%).
217
218 * Client/server transaction timeout option upper limit has been
219 increased from 5000 to 60000 milliseconds.
220
221 * A channel context menu is now featured, by right-clicking over
222 each sampler channel strip.
223
224 * Commented SET CHANNEL MIDI_INPUT_PORT command from
225 qsamplerMainForm::saveSessionFile(), it has no effect.
226
227 * Insert a n #include <unistd.h> on qsamplerMessages.cpp, between
228 a #if !defined(WIN32) clause.
229
230 * An initial non zero value (0.8) is now set for volume of every
231 new sampler channel strip.
232
233 * The order to load/save and setup channel settings is now as
234 suggested in the following lines:
235
236 SET CHANNEL AUDIO_OUTPUT_TYPE ...
237 SET CHANNEL MIDI_INPUT_TYPE ...
238 SET CHANNEL MIDI_INPUT_CHANNEL ...
239 LOAD ENGINE ...
240 LOAD INSTRUMENT ...
241 SET CHANNEL VOLUME ...
242
243
244 0.0.1 2004-06-05 Primordial alpha release.
245

  ViewVC Help
Powered by ViewVC