/[svn]/qsampler/trunk/ChangeLog
ViewVC logotype

Contents of /qsampler/trunk/ChangeLog

Parent Directory Parent Directory | Revision Log Revision Log


Revision 429 - (show annotations) (download)
Tue Mar 8 14:56:05 2005 UTC (19 years ago) by capela
File size: 4440 byte(s)
On-going with new device configuration interface.

1 qsampler - A LinuxSampler Qt GUI Interface
2 ------------------------------------------
3
4 ChangeLog
5
6 0.0.9 2005-03-08 Device configuration work in progress...
7
8 * Device configuration interface preparations.
9
10
11 0.0.5 2005-03-04 Fifth alpha-release.
12
13 * Fixed device driver type channel information gathering,
14 which was severely flawed, dropping all channel session
15 configurations to the default audio driver type (which
16 is ALSA) unexpectedly.
17
18 * Channels are now properly renumbered when saving to a
19 session LSCP script, assuming that it should be always
20 loaded from scratch (i.e. zero channels).
21
22 * Disabled MIDI port setting on channel dialog, and on
23 session file save, as its use is still troublesome.
24
25 * Added new menu and toolbar option: Reset All Channels.
26
27 * Channel setup changes are now properly filtered, as for
28 only those settings that are actually changed gets applied;
29 change information are now also posted to messages window.
30
31 * Drag-and-drop of either session files (LSCP scripts) or
32 instrument files (GIG) are now supported. Multiple files
33 drop is allowed, but it only makes sense for instrument
34 files, each one prompting to create a new sampler channel.
35
36 * Drag-and-drop to an existing channel strip is now also
37 featured, allowing the in-place change of the channel
38 sampler instrument file.
39
40 * Actual instrument names are now optionally retrieved
41 from the instrument file, even though libgig is available,
42 avoiding excessively annoying load times while on the
43 channel dialog, when huge instrument files are selected.
44
45 * Set to ignore the SIGPIPE ("Broken pipe") signal, where
46 available, as the default handler is usually fatal when
47 a JACK client is zombified abruptly.
48
49 * Messages window limit is now enforced only when the line
50 count exceeds in one third the user configured line count
51 maximum; if Qt 3.2.0+ is in use, the QTextView widget is
52 otherwise set to the optimized Qt::LogText format.
53
54
55 0.0.4 2004-11-19 Fourth alpha-release.
56
57 * Instrument index selection now made via combo box widget;
58 actual instrument names are now properly retrieved from
59 the instrument file, provided if libgig is available.
60
61 * Sampler channels strips are just created if, and only if,
62 the respective channel setup dialog is actually accepted,
63 following common user-interface guidelines.
64
65 * Almost complete rewrite of sampler channel strips internal
66 control structures.
67
68 * Sampler reset command action added to menu and toolbar.
69
70 * MIDI channel selection is now a dropdown list, allowing
71 the explicit selection for "All" channels input per sampler
72 channel (omni mode).
73
74 * Channel strip display glass effect has changed background
75 color to black (was green), being now an user option.
76
77 * Minor configure fixes.
78
79
80 0.0.3 2004-07-06 Third alpha-release.
81
82 * Mon-modal intrument file loading and status support.
83
84 * Effective MIDI input port setting on channel dialog,
85 and on session file save.
86
87 * Channel dialog gets sensible engine and driver defaults
88 on create time.
89
90 * Implied channel reset on successful instrument load.
91
92
93 0.0.2 2004-06-15 Pre-revolutionary release.
94
95 * The channel context menu is also accessible by right-clicking
96 over the empty workspace area.
97
98 * Added small wait event loop on qsamplerMainForm::stopServer(),
99 so let local server terminate gracefully and stabilize, and
100 avoiding a probable segfault on exit, which was preventing the
101 correct salvage of settings and configuration.
102
103 * Maximum channel volume percent setting is now a global option,
104 provided to override the default (which is 100%).
105
106 * Client/server transaction timeout option upper limit has been
107 increased from 5000 to 60000 milliseconds.
108
109 * A channel context menu is now featured, by right-clicking over
110 each sampler channel strip.
111
112 * Commented SET CHANNEL MIDI_INPUT_PORT command from
113 qsamplerMainForm::saveSessionFile(), it has no effect.
114
115 * Insert a n #include <unistd.h> on qsamplerMessages.cpp, between
116 a #if !defined(WIN32) clause.
117
118 * An initial non zero value (0.8) is now set for volume of every
119 new sampler channel strip.
120
121 * The order to load/save and setup channel settings is now as
122 suggested in the following lines:
123
124 SET CHANNEL AUDIO_OUTPUT_TYPE ...
125 SET CHANNEL MIDI_INPUT_TYPE ...
126 SET CHANNEL MIDI_INPUT_CHANNEL ...
127 LOAD ENGINE ...
128 LOAD INSTRUMENT ...
129 SET CHANNEL VOLUME ...
130
131
132 0.0.1 2004-06-05 Primordial alpha release.
133

  ViewVC Help
Powered by ViewVC