/[svn]/jsampler/trunk/ChangeLog
ViewVC logotype

Diff of /jsampler/trunk/ChangeLog

Parent Directory Parent Directory | Revision Log Revision Log | View Patch Patch

revision 1311 by iliev, Wed Aug 29 21:23:16 2007 UTC revision 1688 by iliev, Thu Feb 14 16:52:36 2008 UTC
# Line 1  Line 1 
1  CVS HEAD  CVS HEAD
2      * Implemented a backend list with option to manually choose a backend
3        to connect on startup(Edit/Preferences, then click the `Backend' tab)
4        and option to change the backend without restarting JSampler
5        (Actions/Change Backend or Ctrl + B)
6    
7      * Added confirmation messages for removing sampler channels and
8        audio/MIDI devices (Edit/Preferences, then click the `View' tab)
9    
10      * Bug fixes:
11        - fixed bug #66
12        - fixed a null pointer exception in the AudioDevicePane, when JACK
13          driver is used and the additional device parameters are shown.
14        - fixed bug #76
15        - fixed bug #77
16    
17    JSampler v0.8a: 2007-12-06
18      * Added new menu item: Help/Online Tutorial
19    
20      * Implemented support for retrieving instrument information
21        from instrument files
22    
23      * Added support for monitoring the total number of active disk streams
24    
25      * Added Windows file path support
26    
27      * The volume values are now shown in decibels
28    
29      * Added confirmation dialog on exit
30    
31      * Fantasia:
32        - Added option for turning off the custom window decoration
33          (choose Edit/Preferences, then click the `View' tab)
34    
35      * Bug fixes:
36        - The parameter changes were discarded when creating
37          new audio/MIDI device
38        - The orchestras changes were not saved for the next session
39          when orchestras.xml does not exist in the JSampler's home directory
40        - In some cases the sampler configuration was not exported
41          properly to LSCP script
42        - Fixed a bug in the parameter table occuring when combo box
43          is used as cell editor
44        - If there is a cell editing in progress in the parameter table,
45          it is now finalized before creating new audio/MIDI device
46        - Fantasia: Fixed the view of the channel's stream/voice count statistic
47        - Some minor bugfixes and enhancements
48    
49    JSampler v0.7a: 2007-10-15
50      * Added options for choosing default actions when channel is
51        created and assignment of default MIDI/audio drivers to be used
52        (choose Edit/Preferences, then click the `Defaults' tab)
53    
54    * A lists of recently used instrument files, directories,    * A lists of recently used instrument files, directories,
55      database instruments, database directories are now available      database instruments, database directories are now available
56      for quick access, where appropriate.      for quick access, where appropriate.
# Line 7  CVS HEAD Line 59  CVS HEAD
59      instrument/directory, last added instrument to orchestra are      instrument/directory, last added instrument to orchestra are
60      now saved for the next session      now saved for the next session
61    
62      * The last used instrument selection method is now saved
63        for the next session
64    
65      * Implemented automatic scrolling when new channel is created to
66        ensure that it is visible on the screen
67    
68      * Added context menu to the orchestra's instrument table with
69        commands for editing an instrument, deleting an instrument,
70        loading an instrument to a sampler channel and adding an
71        instrument to MIDI instrument map
72    
73      * Implemented more proper retrieval of the MIDI/audio driver settings
74    
75      * Implemented some UI enhancements for speeding up the
76        MIDI instrument mapping process
77    
78      * Implemented new table cell editor for editing string list
79        parameters with possibilities
80    
81      * Added support for escape sequences
82    
83      * Now database instruments and directories can have multiline descriptions
84    
85      * Added support for formatting the instruments database
86        (Choose from the instruments database window Actions/Format Database)
87    
88      * Added options for setting the maximum master and channel volume
89        (choose Edit/Preferences)
90    
91      * JS Classic:
92        - Added new button to sampler channels for starting an instrument editor
93    
94      * Fantasia:
95        - Added scrollbar to the channels pane
96        - Added new menu items: Edit/Add Channel, Edit/Create MIDI Device,
97          Edit/Create Audio Device, View/Toolbar, View/Side Pane,
98          View/Devices Pane
99        - Added button to the channel screen for starting an instrument editor
100          (point the mouse cursor over the channel screen and click 'Edit')
101        - Removed the lock border from non-editable text fields in
102          properties panes and LS Console
103        - Added detailed error dialog
104        - Master volume is now fully implemented
105        - Added options for showing additional device parameters in audio/MIDI
106          device panes (choose Edit/Preferences, then click the `View' tab)
107    
108    * Bug fixes:    * Bug fixes:
109      - fixed bug #49      - fixed bug #49
110      - the first loaded script was not always been executed      - the first loaded script was not always been executed
111        - some javadoc documentation fixes
112        - some minor bugfixes
113    
114      * Some GUI enhancements and code cleanup
115    
116  JSampler v0.6a: 2007-08-10  JSampler v0.6a: 2007-08-10
117    * The Fantasia distribution is now capable of    * The Fantasia distribution is now capable of

Legend:
Removed from v.1311  
changed lines
  Added in v.1688

  ViewVC Help
Powered by ViewVC