* Channels are now properly renumbered when saving to a
  session LSCP script, assuming that it should be always
  loaded from scratch (i.e. zero channels).

* Disabled MIDI port setting on channel dialog, and on
  session file save, as its use is still troublesome.

* Descrimination as for drag-and-drop of instrument files
  has been refined and fixed again.

1 capela 109 qsampler - A LinuxSampler Qt GUI Interface
2     ------------------------------------------
3    
4     ChangeLog
5    
6 capela 409 0.0.5 2005-02-24 Work in progress...
7 capela 327
8 capela 409 * Channels are now properly renumbered when saving to a
9     session LSCP script, assuming that it should be always
10     loaded from scratch (i.e. zero channels).
11    
12     * Disabled MIDI port setting on channel dialog, and on
13     session file save, as its use is still troublesome.
14    
15 capela 404 * Added new menu and toolbar option: Reset All Channels.
16    
17     * Channel setup changes are now properly filtered, as for
18     only those settings that are actually changed gets applied;
19     change information are now also posted to messages window.
20    
21 capela 388 * Drag-and-drop of either session files (LSCP scripts) or
22     instrument files (GIG) are now supported. Multiple files
23     drop is allowed, but it only makes sense for instrument
24     files, each one prompting to create a new sampler channel.
25    
26 capela 395 * Drag-and-drop to an existing channel strip is now also
27     featured, allowing the in-place change of the channel
28     sampler instrument file.
29    
30 capela 341 * Actual instrument names are now optionally retrieved
31     from the instrument file, even though libgig is available,
32     avoiding excessively annoying load times while on the
33     channel dialog, when huge instrument files are selected.
34    
35     * Set to ignore the SIGPIPE ("Broken pipe") signal, where
36 capela 340 available, as the default handler is usually fatal when
37     a JACK client is zombified abruptly.
38    
39 capela 341 * Messages window limit is now enforced only when the line
40 capela 327 count exceeds in one third the user configured line count
41 capela 338 maximum; if Qt 3.2.0+ is in use, the QTextView widget is
42     otherwise set to the optimized Qt::LogText format.
43 capela 327
44    
45 capela 303 0.0.4 2004-11-19 Fourth alpha-release.
46 capela 115
47 capela 299 * Instrument index selection now made via combo box widget;
48     actual instrument names are now properly retrieved from
49     the instrument file, provided if libgig is available.
50    
51 capela 295 * Sampler channels strips are just created if, and only if,
52     the respective channel setup dialog is actually accepted,
53     following common user-interface guidelines.
54    
55 capela 264 * Almost complete rewrite of sampler channel strips internal
56     control structures.
57    
58 capela 255 * Sampler reset command action added to menu and toolbar.
59    
60     * MIDI channel selection is now a dropdown list, allowing
61     the explicit selection for "All" channels input per sampler
62 capela 295 channel (omni mode).
63 capela 255
64     * Channel strip display glass effect has changed background
65 capela 267 color to black (was green), being now an user option.
66 capela 255
67     * Minor configure fixes.
68    
69    
70     0.0.3 2004-07-06 Third alpha-release.
71    
72 capela 145 * Mon-modal intrument file loading and status support.
73    
74 capela 176 * Effective MIDI input port setting on channel dialog,
75     and on session file save.
76 capela 145
77 capela 176 * Channel dialog gets sensible engine and driver defaults
78     on create time.
79 capela 161
80 capela 176 * Implied channel reset on successful instrument load.
81    
82    
83 capela 145 0.0.2 2004-06-15 Pre-revolutionary release.
84    
85 capela 127 * The channel context menu is also accessible by right-clicking
86     over the empty workspace area.
87 capela 130
88 capela 122 * Added small wait event loop on qsamplerMainForm::stopServer(),
89     so let local server terminate gracefully and stabilize, and
90     avoiding a probable segfault on exit, which was preventing the
91     correct salvage of settings and configuration.
92    
93 capela 119 * Maximum channel volume percent setting is now a global option,
94     provided to override the default (which is 100%).
95    
96     * Client/server transaction timeout option upper limit has been
97     increased from 5000 to 60000 milliseconds.
98    
99 capela 118 * A channel context menu is now featured, by right-clicking over
100     each sampler channel strip.
101 capela 115
102 capela 118 * Commented SET CHANNEL MIDI_INPUT_PORT command from
103     qsamplerMainForm::saveSessionFile(), it has no effect.
104    
105     * Insert a n #include <unistd.h> on qsamplerMessages.cpp, between
106 capela 115 a #if !defined(WIN32) clause.
107    
108 capela 118 * An initial non zero value (0.8) is now set for volume of every
109     new sampler channel strip.
110 capela 115
111     * The order to load/save and setup channel settings is now as
112     suggested in the following lines:
113    
114     SET CHANNEL AUDIO_OUTPUT_TYPE ...
115     SET CHANNEL MIDI_INPUT_TYPE ...
116     SET CHANNEL MIDI_INPUT_CHANNEL ...
117     LOAD ENGINE ...
118     LOAD INSTRUMENT ...
119     SET CHANNEL VOLUME ...
120    
121    
122 capela 109 0.0.1 2004-06-05 Primordial alpha release.
123    